G6S
■ Characteristics
Surface-mounting Relay
Single-side Stable
Single-winding Latching
Double-winding Latching
EN60950 certified
Item
Relay Function
G6S-2, G6S-2F,
G6S-2G
G6SU-2, G6SU-2F,
G6SU-2G
G6SK-2, G6SK-2F,
G6SK-2G
G6S-2F-Y, G6S-2G-Y,
G6S-2-Y
Contact resistance *1
Operate (set) time
Release (reset) time
75 m Ω max.
4 ms max.
4 ms max.
Min. set/reset pulse width
Insulation resistance *2
?
10 ms
1,000 M Ω min. (at 500 VDC)
?
Between coil and contacts
2,000 VAC, 50/60 Hz for 1 min
1,000 VAC, 50/60 Hz for 1
min
2,000 VAC, 50/60 Hz for 1
min
Dielectric
strength
Between contacts of different polarity
Between contacts of the same polarity
1,500 VAC, 50/60 Hz for 1 min
1,500 VAC, 50/60 Hz for 1 min
Between set and reset coil
?
500 VAC, 50/60 Hz for 1
min
?
Impulse
withstand
voltage
Between coil and contacts
Between contacts of different polarity
Between contacts of the same polarity
2,500 V (2 × 10 μ s); 1,500 V (10 × 160 μ s) 1,500 V (10 × 160 μ s)
2,500 V (2 × 10 μ s); 1,500 V (10 × 160 μ s)
1,500 V (10 × 160 μ s)
2,500 V (2 × 10 μ s);
1,500 V (10 × 160 μ s)
Vibration
resistance
Shock
resistance
Durability
Destruction
Malfunction
Destruction
Malfunction
Mechanical
Electrical
10 to 55 to 10 Hz, 2.5 mm single amplitude (5 mm double amplitude)
10 to 55 to 10 Hz, 1.65 mm single amplitude (3.3 mm double amplitude)
1,000 m/s 2
750 m/s 2
100,000,000 operations min. (at 36,000 operations/hr)
100,000 operations min. for AC (at 1,800 operations/h with rated load)
100,000 operations min. for DC (at 1,200 operations/h with rated load)
Failure rate (P level) (reference value) *3
10 μ A at 10 m VDC
Ambient operating temperature
Ambient operating humidity
Weight
-40°C to 85°C (with no icing or condensation), and -40°C to 70°C (with no icing or condensation) only for
double-winding latching 24 VDC type and EN60950 standard approved 24 VDC type
5% to 85%
Approx. 2 g
G
6
S
Note: The above values are initial values.
*1. The contact resistance was measured with 10 mA at 1 VDC with a voltage drop method.
*2. The insulation resistance was measured with a 500 VDC megohmmeter applied to the same parts as those used for checking the dielectric strength (except
between the set and reset coil).
*3. This value was measured at a switching frequency of 120 operations/min. This value may vary, depending on switching frequency, operating conditions, expected
reliability level of the relay, etc. It is always recommended to double-check relay suitability under actual load conditions.
■ Engineering Data
● Maximum Switching
Capacity
● Durability
G6S-2F(G)
● Ambient Temperature
vs. Maximum Voltage
(Single-side Stable)
● Ambient Temperature
vs. Maximum Voltage
(Latching)
10
7
500
300
250
G6S
4.5 to 12 VDC
250
5
G6SU
30 VDC resistive load
200
200
3
100
Ambient temperature 23°C
Switching frequency: 1,200
1
AC resistive load
50
30
operations/h
150
150
G6SK
12 VDC max.
0.7
0.5
10
100
G6S
24 VDC
G6S-Y
G6S-Y
100
G6SK
24 VDC
0.3
DC resistive load
5 125 VAC resistive load
Ambient temperature 23°C
3 Switching frequency: 1,800 operations/h
50
12 VDC max. 24 VDC
50
0.1
10
30
50 70 100
300 500 700 1,000
1
0
0.5
1
1.5
2
2.5
3
0
? 40
? 20
0
20
40
60
80
100
0
? 40
? 20
0
20
40
60
80
100
Switching voltage (V)
Switching current (A)
Ambient temperature (°C)
Ambient temperature (°C)
Note: “Maximum voltage” is the maximum voltage that can be applied to the Relay coil.
● Ambient Temperature
vs. Switching Current
(Single-side Stable)
● Ambient Temperature
vs. Switching Current
(Latching)
● Ambient Temperature
vs. Must Operate or Must
Release Voltage
G6S-2F(G)
● Shock Malfunction
G6S-2F(G)
3
3
100
Sample: G6S-2F
Number of Relays: 10 pcs
Y
1,000
Energized
2
G6S
12 VDC max.
2
G6SU 12 VDC max.
G6SU 24 VDC
G6SK
80
60
max.
X
min.
X
1,000
800
600
De-
400 energized
200
Z
1,000
12 VDC max.
1
G6S-Y
24 VDC
G6S
24 VDC
1
G6SK 24 VDC
40
20
max.
X
min.
1,000
Z'
Shock direction
200
400
600
800
1,000
X'
0
40
50
G6S-Y
12 VDC max.
60 70
80
90
100
0
40
50
60
70
80
90
100
0
? 60
? 40 ? 20
0
20
40
Must operate voltage
Must release voltage
60 80 100 120
X X'
Y
Z
Z'
1,000
Y'
Unit: m/s 2
Sample: G6S-2F
Number of Relays: 10 pcs
Ambient temperature (°C)
Ambient temperature (°C)
Ambient temperature (°C)
Y'
Conditions: Shock is applied in ±X, ±Y, and
±Z directions three times each
with and without energizing the
Relays to check the number of
contact malfunctions.
3
相关PDF资料
G6WU-1P DC9 RELAY RF SPDT 10MA 9V
G6Y-1 DC9 RELAY RF SPDT 10MA 9V
G6ZK-1F-TR DC5 RELAY RF SPDT 10MA 5V
G6ZU-1F DC9 RELAY RF SPDT 10MA 9V
G7J-2A2B-B-W1 AC200/240 RELAY GEN PURPOSE 4PST 25A 240V
G7Z-4A-20Z DC24 RELAY GEN PURPOSE 4PST 40A 24V
G8HN-1C2T-R DC12 RELAY AUTOMOTIVE SPDT 10A 12V
G8JN-1C7T-DC12 RELAY AUTOMOTIVE SPDT 35A 12V
相关代理商/技术参数
G6S-2F-3-DC4.5 制造商:Omron Corporation 功能描述:
G6S2F3DC45 制造商:Omron Electronic Components LLC 功能描述:LOW SIGNAL RELAY - Bulk 制造商:Omron Electronic Components LLC 功能描述:RELAY TELECOM DPDT 2A 4.5V
G6S-2F-3-TR DC4.5 功能描述:低信号继电器 - PCB SMT Tape and Reel Relay RoHS:否 制造商:NEC 触点形式:2 Form C (DPDT-BM) 触点电流额定值: 线圈电压:5 V 最大开关电流:1 A 线圈电流:1 A 线圈类型:Non-Latching 功耗:140 mW 端接类型:SMT 绝缘: 介入损耗:
G6S-2F-3-TR-DC4.5 制造商:Omron Corporation 功能描述:
G6S2F3TRDC45 制造商:Omron Electronic Components LLC 功能描述:SMT TAPE AND REEL RELAY - Bulk 制造商:Omron Electronic Components LLC 功能描述:RELAY TELECOM DPDT 2A 4.5V
G6S-2F-3VDC 制造商:Omron 功能描述:Electromechanical Relay DPDT 2A 3VDC Surface Mount
G6S2F5VDC 制造商:Omron Corporation 功能描述:
G6S-2F-5VDC 制造商:Omron Corporation 功能描述: 制造商:Omron Corporation 功能描述:POWER/SIGNAL RELAY, DPDT, MOMENTARY, 0.028A (COIL), 5VDC (COIL), 140mW (COIL), 2A (CONTACT), 30VDC (CONTACT), SURFACE MOUNT-STRAIGHT